You need to choose options for product.
Sale
-
files/Battery_Monitor_BM_500_-_1.jpg
-
files/Metal_Bezel_1.jpg
-
files/500-Amp-Battery-Monitor-with-Shunt.jpg
-
files/Battery-Monitor-and-Box.jpg
-
files/Battery_Monitor_BM_500_-_2.jpg
-
files/Battery_Monitor_BM_500_-_3.jpg
-
files/Battery_Monitor_BM_500_-_4.jpg
-
files/Battery_Monitor_BM_500_-_5.jpg
-
files/Battery_Monitor_BM_500_-_6.jpg
-
files/Battery_Monitor_BM_500_-_7.jpg
-
files/Battery_Monitor_BM_500_-_8.jpg
-
files/Battery_Monitor_BM_500_-_9.jpg
-
files/Battery_Monitor_BM_500_-_10.jpg
-
files/Metal_Bezel.jpg
Rich Solar RS-BM500 1500A Battery Monitor with Shunt | 8–120V | Accurate Battery Status & Easy Installation
- Regular price
- $99.99
- Sale price
- $79.99
- Regular price
- $99.99
- Sale price
- $79.99
Sale
Estimated shipping time
Estimated shipping time
We offer free shipping across the United States, with orders processed within 1–2 business days and delivered in about 4–7 business days. Every order comes with tracking and insurance, and our team is here to help if your package is delayed, lost, or arrives damaged. Returns are accepted within 30 days, with no cost for return shipping. Please ensure your shipping address is accurate to avoid delays. Refer to full policy here.
What is your Return Policy?
What is your Return Policy?
We accept returns within 30 days of delivery if items are unused, undamaged, and in their original packaging. Return shipping is free, and refunds are processed within 7 days after inspection to your original payment method. Defective, damaged, or incorrect items will be replaced or refunded at no cost, while change-of-mind returns may incur a restocking fee. Some items (custom, perishable, intimate goods, gift cards, software) are non-returnable. Refer to full policy here.
Take the guesswork out of your battery performance with the Rich Solar RS-BM500 1500A Battery Monitor with Shunt. Designed for accuracy, reliability, and ease of use, this powerful monitor gives you real-time insight into your battery’s capacity, voltage, current, and overall health. Whether you’re managing a solar power system, RV setup, marine batteries, or an off-grid installation, the RS-BM500 ensures you always know exactly how much energy you have left.
The large, easy-to-read remote display can be wall-mounted for convenient viewing, while the heavy-duty shunt ensures precise measurements by connecting directly to your battery’s negative terminal. With a wide voltage range (8–120V) and an impressive ±1% measurement accuracy, you’ll enjoy dependable performance for years to come.
Built for both professionals and DIY installers, the RS-BM500 comes complete with all necessary cables, connectors, and an intuitive wiring setup — making installation quick and straightforward.
Key Features
- Wide Voltage Range – Monitors battery systems from 8V to 120V for maximum compatibility.
- High Current Capacity – Supports up to 1500A with precise measurement.
- ±1% Accuracy – Provides dependable readings for capacity, voltage, and current.
- Real-Time Monitoring – Tracks amp-hours, charge/discharge current, and remaining capacity.
- Low Power Consumption – Only 10mA working dissipation; 1mA standby.
- Easy Installation – Wall-mountable display with included wiring and shunt.
- Durable Design – Built for long-term use in solar, RV, marine, and off-grid setups.
Specifications
| Specification | Details |
|---|---|
| Model | RS-BM500 |
| Voltage Range | 8–120V |
| Current Range | 0.1–9999Ah |
| Capacity Setting Value | 0–500A |
| Working Dissipation | 10mA |
| Standby Dissipation | 1mA |
| Capacity Accuracy | ±1.0% |
| Voltage Accuracy | ±1.0% |
| Current Accuracy | ±1.0% |
| Backlight On Current | 80mA |
| Installation Type | Wall-mounted display with shunt |
| Included Accessories | Shunt, shielded cable, B+ wire, mounting hardware |
| Applications | Solar power systems, RVs, boats, off-grid setups |
Installation Overview
- Disconnect all wires from the negative battery terminal.
- Mount the Shunt as close to the battery as possible.
- Connect the “B-” side of the shunt directly to the battery’s negative terminal (no other connections for accurate readings).
- Use the included B+ wire to connect the shunt’s B+ terminal to the battery’s positive terminal.
- Run the shielded cable from the shunt to the wall-mounted remote display.
- Mount the display in your chosen location using a drill and jigsaw cutout.
- Secure all connections and power on for accurate battery monitoring.
Documents
⚠️ California Proposition 65 Warning: This product can expose you to chemicals, including lead, which is known to the State of California to cause cancer and reproductive harm. For more information, visit www.P65Warnings.ca.gov.
Customers also browsed
-
FREE SHIPPING IN USA
Free shipping with every order. See policy
-
EASY RETURNS
30 day hassle-free returns with free return shipping. See policy
-
PREMIUM CUSTOMER SUPPORT
Connect with us through live chat, email,
or phone, and we will address any questions you may have! Contact Us
-
SECURE ENCRYPTED PAYMENTS
We utilize advanced encryption to
ensure there is never an issue with your privacy. See policy